Add to Cart
Laser Positioning Body Infrared Thermometer Intelligent Backlight Smart Design
Specification
1, Temperature measurement button
2, Menu key
3, Temperature memory plus key
4, Temperature memory minus sign key
5, Temperature measurement mode switch button
6, LCD display
7, Plastic shell
8, Battery box
|
|
---|---|
Measuring range | 32.0℃-42.9℃ (89.6℉-109.2℉)in body temperature mode |
Measurement accuracy | 35.0℃-42.0℃:±0.2℃ |
Tri-color backlight | 32.0℃~37.4℃:Green 37.5℃~38.4℃:Yellow
38.5℃~42.9℃:Red
|
Specification
Technical Parameters
Measuring distance |
3cm~5cm
|
Measuring range
|
32.0℃~42.9℃ 89.6℉~109.2℉ |
Resolution
|
0.1℃/℉
|
Power supply
|
AAA battery *2 (alkaline) |
Low battery prompt
|
2.5±0.2V
|
Memory function
|
32groups memory
|
Temperature unit
|
℃,℉
|
Product size
|
161×90.5×45.5MM
|
Use period
|
5 years
|
Working conditions
|
10℃~ 40℃(50℉~ 104℉),RH≤93%,70kPa~ 106kPa
|
Storage conditions
|
-20℃~ 55℃(-4℉~ 131℉),RH≤93%,50kPa~ 106kPa
|
Measuring area
|
Forehead
|
Measuring method
|
Non-contact
|
Measurement accuracy |
±0.2℃(35.0℃~42℃) ±0.3℃(<35℃or >42℃) |
Power consumption
|
Off state≤90uW Working state≤90uW
|
Display
|
LCD
|
Automatic shutdown
|
10S
|
Product weight
|
94g(without battery)
|
Production date
|
see outer box
|
1. Add or subtract memory key: short press to query the measurement record, automatically record 32 sets of test data, and automatically delete the previous record if more than 32 sets are exceeded, and always retain the last 32 sets of data;
2. Menu key: short press to switch between Fahrenheit and Celsius;
3. Temperature measurement button: short press to measure the temperature, and the LCD will display the temperature value in the current mode;
4. Body temperature mode (Body), the screen will display three colors of backlight. As shown in the figure below, LO is displayed below 32 degrees, and HI is displayed above 42 degrees. The backlight of Surface mode is only green;
1, Temperature measurement button
2, Menu key
3, Temperature memory plus key
4, Temperature memory minus sign key
5, Temperature measurement mode switch button
6, LCD display
7, Plastic shell
8, Battery box
1. Add or subtract memory key: short press to query the measurement record, automatically record 32 sets of test data, and automatically delete the previous record if more than 32 sets are exceeded, and always retain the last 32 sets of data;
2. Menu key: short press to switch between Fahrenheit and Celsius;
3. Temperature measurement button: short press to measure the temperature, and the LCD will display the temperature value in the current mode;
4. Body temperature mode (Body), the screen will display three colors of backlight. As shown in the figure below, LO is displayed below 32 degrees, and HI is displayed above 42 degrees. The backlight of Surface mode is only green;
Advice before use
Infrared forehead thermometers have high requirements on the surrounding environment. The correct method of use is the key to accurate testing.
(1)This product is an infrared forehead thermometer that professionally measures the temperature of the human body. According to the difffference of human skin, the measured temperature will be difffferent.
(2) When the room temperature changes greatly, the infrared frontal thermometer should be placed in the room for 20 minutes before use.
(3) When the person to be measured comes from a place with a large difffference in temperature from the measurement environment, they should stay in the test environment for at least 5 minutes, and wait until
the temperature is consistent with the environment before measuring.
(4) The environment around the person to be tested must be stable. Do not test in places with large air flflow such asfans and air outlets of air conditioners.
Precautions
(1) Please do not use in the environment that does not meet the requirements.
(2) Please do not stay near the electromagnetic range (such as radio, mobile phone, etc.), otherwise it will affect product
performance.
(3) Please do not bump or drop this product, if it is damaged, stop using it.
(4) Please wipe the surface of the product with alcohol gentaly when it needs clean.
(5) If there is a problem with the product, do not attempt to repair it yourself, please contact your dealer,
(6) In view of the many factors that affect the accuracy of the measurement, this product is not a substitute for a doctor's diagnosis. It is only used for screening. If an abnormality occurs, please seek medical treatment in time.